Florida Fire Solutions  |  License #FPC25-000017

Kitchen Hood Fire Suppression Inspection in Sunrise

NFPA 96 bi-annual kitchen hood fire suppression inspections for restaurants, hotels, and commercial kitchens in Sunrise. Licensed contractor. Full documentation. Same-visit certification tag.

Kitchen Hood Inspection in Sunrise

Licensed Kitchen Hood Fire Suppression Inspection for Sunrise Restaurants and Commercial Kitchens

Florida Fire Solutions performs NFPA 96-required kitchen hood fire suppression inspections for restaurants, hotels, corporate cafeterias, and food service operations throughout Sunrise. Every inspection is performed by a licensed fire protection contractor, fully documented in a written service report, and submitted to Sunrise Fire Rescue.

Sunrise is anchored by Sawgrass Mills Mall, one of the largest outlet malls in the United States, and the Amerant Bank Arena. The food court and restaurant tenant operations inside Sawgrass Mills represent a significant concentration of commercial kitchens in a single complex. Arena concession and event catering kitchens at Amerant Bank Arena operate on intensive event-driven cycles. The hotel properties along the Sawgrass corridor serve arena visitors and mall shoppers with active food and beverage operations.

High-volume food court and arena kitchen operations in Sunrise run cooking equipment at near-continuous capacity on event days, generating accelerated grease accumulation in hood systems between inspection cycles. The six-month NFPA 96 inspection schedule is especially important for these high-throughput kitchen environments. Sunrise Fire Rescue enforces kitchen hood compliance for all commercial cooking operations in the city.

Sunrise Fire Rescue enforces NFPA 96 kitchen hood compliance throughout the city. Commercial building inspections for high-volume food court and arena food service facilities include kitchen hood certification tag verification. We work with Sunrise restaurant operators who have received fire marshal notices and need to get documented quickly before their correction deadline. See our full kitchen hood inspection service for more on how the program works.

NFPA 96 Requires Inspection Every Six Months

Sunrise commercial kitchens with hood suppression systems must be inspected by a licensed fire protection company every six months. Sunrise Fire Rescue checks certification tags during routine commercial building inspections. An expired tag is a citable violation with a correction deadline. We serve Sunrise restaurants, hotels, and commercial kitchens with licensed bi-annual inspection and same-visit documentation.

Get Scheduled →
2x
Per Year
4
Counties
100%
Documented

License #FPC25-000017. Every inspection includes functional testing, fusible link replacement, gas and electrical shutoff verification, and a written service report submitted to the Sunrise Fire Rescue.

Not sure when your last kitchen hood inspection was? We’ll confirm your compliance status and get you on the calendar fast.
Call (305) 707-3473
Inspection Scope

What Does the Kitchen Hood Inspection Include?

A proper NFPA 96 kitchen hood inspection is not a visual check. Every component in the suppression system is tested and serviced so the system is ready to respond to a real fire. Here is what every Sunrise inspection covers.

  • All suppression nozzles inspected for grease blockage, nozzle caps replaced, and extinguishing agent lines cleared for full discharge capability
  • Manual pull station tested and pressure gauges verified for correct PSI to confirm the agent cartridge is within operational range
  • Gas shutoff valve and electrical shutoff tested to confirm both cut off immediately on system activation
  • Fusible links cut to simulate heat activation and verify the system responds correctly, then replaced with new date-stamped links
  • Hood and exhaust duct condition assessed for grease accumulation affecting system performance
  • Cooking equipment configuration verified against nozzle coverage to confirm the current equipment layout matches the system design
  • System tagged with current certification date; written service report completed and submitted to Sunrise Fire Rescue

Kitchen Hood Suppression Inspection Scope for Sunrise Commercial Kitchens

Every inspection performed by Florida Fire Solutions in Sunrise covers all items below. No items are skipped or deferred to a follow-up visit.

Inspection ItemWhat We DoWhy It Matters
Fusible linksCut and replaced with new date-stamped links at every inspectionFusible links are a consumable safety component; reusing old links means the system may not trigger correctly in a real fire
Nozzles and capsNozzles inspected for grease blockage; caps replaced to keep nozzles clear between inspectionsBlocked nozzles prevent the suppression agent from reaching the cooking surface where the fire is
Gas shutoffTested to confirm the gas supply to all cooking equipment under the hood cuts off on system activationA kitchen fire fed by continuous gas supply cannot be effectively suppressed
Electrical shutoffTested to confirm cooking equipment electrical power shuts off on system activationElectrical ignition sources must be removed when the suppression agent discharges
Agent cartridge pressurePressure gauge verified against manufacturer specificationA low-pressure cartridge may not fully discharge the suppression agent across all nozzles
Manual pull stationPull station function tested for correct cable operationThe manual pull must work reliably if staff need to activate the system before automatic heat detection triggers
Service documentationWritten service report completed and certification tag affixed to the systemRequired by NFPA 96 and Sunrise Fire Rescue for compliance verification during commercial building inspections
Sunrise Context

Why Kitchen Hood Inspections Matter for Sunrise Restaurants

Sunrise’s restaurant and food service market includes high-volume mall food court operators, chain restaurants, arena food service, and hotel kitchens along Sunrise Boulevard, University Drive, and the Sawgrass Mills Mall corridor. Sunrise Fire Rescue routinely enforces kitchen hood inspection compliance throughout the city.

Sunrise is anchored by Sawgrass Mills Mall, one of the largest outlet malls in the United States, and the Amerant Bank Arena. The food court and restaurant tenant operations inside Sawgrass Mills represent a significant concentration of commercial kitchens in a single complex. Arena concession and event catering kitchens at Amerant Bank Arena operate on intensive event-driven cycles. The hotel properties along the Sawgrass corridor serve arena visitors and mall shoppers with active food and beverage operations.

High-volume food court and arena kitchen operations in Sunrise run cooking equipment at near-continuous capacity on event days, generating accelerated grease accumulation in hood systems between inspection cycles. The six-month NFPA 96 inspection schedule is especially important for these high-throughput kitchen environments. Sunrise Fire Rescue enforces kitchen hood compliance for all commercial cooking operations in the city.

Schedule Your Sunrise Inspection
Got a fire marshal notice or upcoming inspection? We respond quickly and get your system documented before the deadline.
Contact Us Today
Why Choose Us

Why Sunrise Restaurant Owners Choose Florida Fire Solutions

A lot of companies will hang a tag and call it done. We perform the full NFPA 96 scope, document everything, and report to your local fire authority. Here is what sets our company apart.

State Licensed Contractor
We hold active Florida fire protection contractor license #FPC25-000017. Every kitchen hood inspection our company performs in Sunrise is backed by a licensed contractor who answers to the state of Florida for the work we do.
Full NFPA 96 Scope
We perform every item required by NFPA 96 at every inspection. Fusible links replaced, nozzles and caps serviced, gas and electrical shutoffs tested, agent pressure verified, and full documentation produced. Nothing deferred to a follow-up.
Sunrise Fire Rescue Documentation
Our company submits inspection reports to Sunrise Fire Rescue after every Sunrise inspection and affixes the current certification tag to the system. You receive a copy of the service report for your own records and for presentation to the fire marshal.
Fast Scheduling for Fire Marshal Notices
If you have received a notice from Sunrise Fire Rescue regarding your kitchen hood inspection, our company prioritizes scheduling to get your system documented before the correction deadline. Call (305) 707-3473 directly for the fastest response.
Schedule Your Kitchen Hood Inspection
Common Questions

Frequently Asked Questions: Kitchen Hood Inspection in Sunrise

NFPA 96 requires kitchen hood fire suppression systems to be inspected every six months by a licensed fire protection company. That means twice per year for every Sunrise commercial kitchen with a suppression system installed under the hood. Sunrise Fire Rescue enforces this requirement during routine commercial building inspections and checks for a current certification tag on the system.

An expired or missing certification tag is a citable violation during a Sunrise Fire Rescue commercial building inspection. You will receive a notice of violation with a deadline to get the system inspected and documented by a licensed contractor. Call us immediately if this happens. We prioritize scheduling for Sunrise restaurant operators dealing with fire marshal notices.

Every NFPA 96 inspection we perform in Sunrise covers the full scope: fusible link replacement, suppression nozzle and cap service, gas shutoff valve testing, electrical shutoff testing, agent cartridge pressure verification, manual pull station testing, and a written service report with a new certification tag. No items are deferred to a follow-up visit.

Yes. NFPA 96 applies to all commercial cooking operations regardless of the business model. Hotel kitchens, corporate cafeterias, catering operations, food halls, and ghost kitchens in Sunrise all require the same bi-annual inspection as traditional restaurants. If the operation produces heat and grease under a commercial hood with a suppression system installed, the six-month inspection cycle applies.

Yes. We recommend scheduling both inspections at the start of each year so the dates are locked in and you receive reminders before each visit. This eliminates the risk of arriving at your next Sunrise Fire Rescue inspection with an expired tag because the second visit was overlooked.

Ready to get your kitchen hood inspection on the calendar? We handle the inspection, the tag, and the paperwork.
Request a Quote

Schedule Your Kitchen Hood Inspection in Sunrise

Licensed fire protection contractor. NFPA 96 compliant inspection. Written service report delivered same day. Reporting to Sunrise Fire Rescue included. Serving Sunrise and all of Broward County.

Or call directly (305) 707-3473

Reviewed by the Florida Fire Solutions Team. Licensed fire protection contractor, License #FPC25-000017. Serving restaurants, hotels, and commercial kitchens throughout Sunrise and Broward County. All content reflects current NFPA 96 requirements and Florida fire code standards enforced by the Sunrise Fire Rescue and the Florida State Fire Marshal.

Last updated: May 2025