Florida Fire Solutions  |  License #FPC25-000017

Kitchen Hood Fire Suppression Inspection in Palm Beach Gardens

NFPA 96 bi-annual kitchen hood fire suppression inspections for restaurants, hotels, and commercial kitchens in Palm Beach Gardens. Licensed contractor. Full documentation. Same-visit certification tag.

Kitchen Hood Inspection in Palm Beach Gardens

Licensed Kitchen Hood Fire Suppression Inspection for Palm Beach Gardens Restaurants and Commercial Kitchens

Florida Fire Solutions performs NFPA 96-required kitchen hood fire suppression inspections for restaurants, hotels, corporate cafeterias, and food service operations throughout Palm Beach Gardens. Every inspection is performed by a licensed fire protection contractor, fully documented in a written service report, and submitted to Palm Beach Gardens Fire Rescue.

Palm Beach Gardens is an affluent northern Palm Beach County city with a strong upscale dining market along PGA Boulevard. The city’s golf resort properties, including PGA National Resort, run full-service hotel restaurant and banquet kitchen operations that require bi-annual NFPA 96 inspection. The Gardens Mall and surrounding retail corridor concentrate restaurant tenants and food court operators. Corporate campuses in the city’s significant office market add employee cafeteria demand.

Golf resort and country club kitchen operations in Palm Beach Gardens serve high-volume events including tournaments, corporate outings, and member dining that peak seasonally. These kitchens run at capacity during event periods and produce the grease accumulation conditions where current suppression system documentation is most critical. Palm Beach Gardens Fire Rescue enforces kitchen hood compliance for all commercial cooking operations in the city.

Palm Beach Gardens Fire Rescue enforces NFPA 96 kitchen hood compliance throughout the city. Golf resort, hotel, and corporate food service operations are subject to routine commercial building inspections. We work with Palm Beach Gardens restaurant operators who have received fire marshal notices and need to get documented quickly before their correction deadline. See our full kitchen hood inspection service for more on how the program works.

NFPA 96 Requires Inspection Every Six Months

Palm Beach Gardens commercial kitchens with hood suppression systems must be inspected by a licensed fire protection company every six months. Palm Beach Gardens Fire Rescue checks certification tags during routine commercial building inspections. An expired tag is a citable violation with a correction deadline. We serve Palm Beach Gardens restaurants, hotels, and commercial kitchens with licensed bi-annual inspection and same-visit documentation.

Get Scheduled →
2x
Per Year
4
Counties
100%
Documented

License #FPC25-000017. Every inspection includes functional testing, fusible link replacement, gas and electrical shutoff verification, and a written service report submitted to the Palm Beach Gardens Fire Rescue.

Not sure when your last kitchen hood inspection was? We’ll confirm your compliance status and get you on the calendar fast.
Call (305) 707-3473
Inspection Scope

What Does the Kitchen Hood Inspection Include?

A proper NFPA 96 kitchen hood inspection is not a visual check. Every component in the suppression system is tested and serviced so the system is ready to respond to a real fire. Here is what every Palm Beach Gardens inspection covers.

  • All suppression nozzles inspected for grease blockage, nozzle caps replaced, and extinguishing agent lines cleared for full discharge capability
  • Manual pull station tested and pressure gauges verified for correct PSI to confirm the agent cartridge is within operational range
  • Gas shutoff valve and electrical shutoff tested to confirm both cut off immediately on system activation
  • Fusible links cut to simulate heat activation and verify the system responds correctly, then replaced with new date-stamped links
  • Hood and exhaust duct condition assessed for grease accumulation affecting system performance
  • Cooking equipment configuration verified against nozzle coverage to confirm the current equipment layout matches the system design
  • System tagged with current certification date; written service report completed and submitted to Palm Beach Gardens Fire Rescue

Kitchen Hood Suppression Inspection Scope for Palm Beach Gardens Commercial Kitchens

Every inspection performed by Florida Fire Solutions in Palm Beach Gardens covers all items below. No items are skipped or deferred to a follow-up visit.

Inspection ItemWhat We DoWhy It Matters
Fusible linksCut and replaced with new date-stamped links at every inspectionFusible links are a consumable safety component; reusing old links means the system may not trigger correctly in a real fire
Nozzles and capsNozzles inspected for grease blockage; caps replaced to keep nozzles clear between inspectionsBlocked nozzles prevent the suppression agent from reaching the cooking surface where the fire is
Gas shutoffTested to confirm the gas supply to all cooking equipment under the hood cuts off on system activationA kitchen fire fed by continuous gas supply cannot be effectively suppressed
Electrical shutoffTested to confirm cooking equipment electrical power shuts off on system activationElectrical ignition sources must be removed when the suppression agent discharges
Agent cartridge pressurePressure gauge verified against manufacturer specificationA low-pressure cartridge may not fully discharge the suppression agent across all nozzles
Manual pull stationPull station function tested for correct cable operationThe manual pull must work reliably if staff need to activate the system before automatic heat detection triggers
Service documentationWritten service report completed and certification tag affixed to the systemRequired by NFPA 96 and Palm Beach Gardens Fire Rescue for compliance verification during commercial building inspections
Palm Beach Gardens Context

Why Kitchen Hood Inspections Matter for Palm Beach Gardens Restaurants

Palm Beach Gardens’s restaurant and food service market includes upscale suburban restaurants, hotel dining, golf resort food service, corporate cafeterias, and mall food court operators along PGA Boulevard, Alternate A1A, and the Gardens Mall corridor. Palm Beach Gardens Fire Rescue routinely enforces kitchen hood inspection compliance throughout the city.

Palm Beach Gardens is an affluent northern Palm Beach County city with a strong upscale dining market along PGA Boulevard. The city’s golf resort properties, including PGA National Resort, run full-service hotel restaurant and banquet kitchen operations that require bi-annual NFPA 96 inspection. The Gardens Mall and surrounding retail corridor concentrate restaurant tenants and food court operators. Corporate campuses in the city’s significant office market add employee cafeteria demand.

Golf resort and country club kitchen operations in Palm Beach Gardens serve high-volume events including tournaments, corporate outings, and member dining that peak seasonally. These kitchens run at capacity during event periods and produce the grease accumulation conditions where current suppression system documentation is most critical. Palm Beach Gardens Fire Rescue enforces kitchen hood compliance for all commercial cooking operations in the city.

Schedule Your Palm Beach Gardens Inspection
Got a fire marshal notice or upcoming inspection? We respond quickly and get your system documented before the deadline.
Contact Us Today
Why Choose Us

Why Palm Beach Gardens Restaurant Owners Choose Florida Fire Solutions

A lot of companies will hang a tag and call it done. We perform the full NFPA 96 scope, document everything, and report to your local fire authority. Here is what sets our company apart.

State Licensed Contractor
We hold active Florida fire protection contractor license #FPC25-000017. Every kitchen hood inspection our company performs in Palm Beach Gardens is backed by a licensed contractor who answers to the state of Florida for the work we do.
Full NFPA 96 Scope
We perform every item required by NFPA 96 at every inspection. Fusible links replaced, nozzles and caps serviced, gas and electrical shutoffs tested, agent pressure verified, and full documentation produced. Nothing deferred to a follow-up.
Palm Beach Gardens Fire Rescue Documentation
Our company submits inspection reports to Palm Beach Gardens Fire Rescue after every Palm Beach Gardens inspection and affixes the current certification tag to the system. You receive a copy of the service report for your own records and for presentation to the fire marshal.
Fast Scheduling for Fire Marshal Notices
If you have received a notice from Palm Beach Gardens Fire Rescue regarding your kitchen hood inspection, our company prioritizes scheduling to get your system documented before the correction deadline. Call (305) 707-3473 directly for the fastest response.
Schedule Your Kitchen Hood Inspection
Common Questions

Frequently Asked Questions: Kitchen Hood Inspection in Palm Beach Gardens

NFPA 96 requires kitchen hood fire suppression systems to be inspected every six months by a licensed fire protection company. That means twice per year for every Palm Beach Gardens commercial kitchen with a suppression system installed under the hood. Palm Beach Gardens Fire Rescue enforces this requirement during routine commercial building inspections and checks for a current certification tag on the system.

An expired or missing certification tag is a citable violation during a Palm Beach Gardens Fire Rescue commercial building inspection. You will receive a notice of violation with a deadline to get the system inspected and documented by a licensed contractor. Call us immediately if this happens. We prioritize scheduling for Palm Beach Gardens restaurant operators dealing with fire marshal notices.

Every NFPA 96 inspection we perform in Palm Beach Gardens covers the full scope: fusible link replacement, suppression nozzle and cap service, gas shutoff valve testing, electrical shutoff testing, agent cartridge pressure verification, manual pull station testing, and a written service report with a new certification tag. No items are deferred to a follow-up visit.

Yes. NFPA 96 applies to all commercial cooking operations regardless of the business model. Hotel kitchens, corporate cafeterias, catering operations, food halls, and ghost kitchens in Palm Beach Gardens all require the same bi-annual inspection as traditional restaurants. If the operation produces heat and grease under a commercial hood with a suppression system installed, the six-month inspection cycle applies.

Yes. We recommend scheduling both inspections at the start of each year so the dates are locked in and you receive reminders before each visit. This eliminates the risk of arriving at your next Palm Beach Gardens Fire Rescue inspection with an expired tag because the second visit was overlooked.

Ready to get your kitchen hood inspection on the calendar? We handle the inspection, the tag, and the paperwork.
Request a Quote

Schedule Your Kitchen Hood Inspection in Palm Beach Gardens

Licensed fire protection contractor. NFPA 96 compliant inspection. Written service report delivered same day. Reporting to Palm Beach Gardens Fire Rescue included. Serving Palm Beach Gardens and all of Palm Beach County.

Or call directly (305) 707-3473

Reviewed by the Florida Fire Solutions Team. Licensed fire protection contractor, License #FPC25-000017. Serving restaurants, hotels, and commercial kitchens throughout Palm Beach Gardens and Palm Beach County. All content reflects current NFPA 96 requirements and Florida fire code standards enforced by the Palm Beach Gardens Fire Rescue and the Florida State Fire Marshal.

Last updated: May 2025