Florida Fire Solutions • License #FPC25-000017

Wet Chemical Class K Fire Extinguisher Service
Restaurants and Commercial Kitchens, South Florida

Licensed Class K wet chemical fire extinguisher inspection and service for restaurants and commercial kitchens across Miami-Dade, Broward, Palm Beach, and Monroe County. NFPA 10 and NFPA 96 compliant.

Class K Wet Chemical

Why Do Restaurants and Commercial Kitchens Require Class K Fire Extinguishers?

Commercial kitchens using deep fryers, woks, griddles, and other high-temperature cooking equipment produce cooking oil fires that standard ABC dry chemical extinguishers cannot effectively suppress. Class K wet chemical extinguishers use a potassium-based alkaline solution that reacts with burning cooking oil through saponification, creating a soapy foam layer that seals the oil surface and prevents re-ignition. Under NFPA 10 and NFPA 96, a listed Class K extinguisher within 30 feet of commercial cooking equipment is required for every commercial kitchen. Florida Fire Solutions performs Class K extinguisher service for restaurants and commercial kitchens across all four South Florida counties.

South Florida's restaurant market is one of the densest in the country, with commercial kitchens in standalone restaurants, hotel food service operations, hospital cafeterias, school food service, food truck commissaries, ghost kitchens, and thousands of smaller operations throughout the region. Every kitchen with commercial cooking equipment is required to have a currently inspected and tagged Class K extinguisher. Class K extinguisher compliance is one of the most actively enforced fire code requirements in the region.

Class K extinguishers work in conjunction with the kitchen hood fire suppression system, not as a replacement for it. The hood suppression system is designed to automatically suppress a cooking fire at the appliance level. The Class K portable extinguisher is the manual backup kitchen staff can use to address a fire the hood system missed, a fire outside hood coverage, or a residual fire after the hood has discharged. Both must be current and functional for the kitchen to be in full compliance. We also service kitchen hood suppression systems under our kitchen hood fire suppression inspection program.

The 5-year hydrostatic test requirement for Class K units is commonly missed in South Florida restaurants. Many operators know about the annual inspection but are unaware that the cylinder must be hydrostatically tested every 5 years. Fire marshals check the Class K unit for both a current annual tag and a current hydrostatic test stamp. A restaurant with a current annual tag but no hydrostatic test stamp on a unit older than 5 years can still receive a citation. The Florida State Fire Marshal enforces both requirements.

An ABC Extinguisher Cannot Substitute for a Class K in a Commercial Kitchen

Using an ABC dry chemical extinguisher on a commercial cooking oil fire can cause burning oil to splash and spread, making the fire significantly worse. Class K wet chemical is required by NFPA 10 and NFPA 96 within 30 feet of commercial cooking equipment. Florida Fire Solutions holds license #FPC25-000017 and services Class K extinguishers for restaurants across all four South Florida counties.

Request a Service Appointment →
Annual
Inspection
5 Yr
Hydrostatic
100%
Documented

License #FPC25-000017. Every inspection is documented with a written service report and the extinguisher is tagged per Florida Administrative Code 69A-21 and NFPA 10.

Restaurant or commercial kitchen with a Class K extinguisher not inspected or not hydrostatically tested within 5 years? Both requirements are actively enforced by fire marshals during restaurant inspections.
Call (305) 707-3473
Service Requirements

What Service Does a Class K Wet Chemical Extinguisher Require?

Class K extinguisher service requirements differ from ABC dry chemical in several important ways, particularly around the liquid agent and the hydrostatic test interval.

  • Monthly visual check (owner responsibility): location near cooking equipment confirmed; no visible damage; tamper seal intact; manufacturer service label visible
  • Annual inspection: full NFPA 10 annual scope; gauge in operable range; agent level confirmed; tamper seal intact; operating instructions legible and facing forward; annual tag affixed
  • Agent level verification: Class K units contain liquid wet chemical agent; agent level confirmed during inspection per manufacturer procedure
  • 5-year hydrostatic pressure test: cylinder pressurized to 1.5 times service pressure; expansion measured; test date stamped on cylinder; cylinder condemned if failed
  • Manufacturer-specified internal maintenance: wet chemical units require internal maintenance per manufacturer specification, which may differ from the standard NFPA 10 6-year schedule
  • Recharge after any use: wet chemical liquid agent recharged to specified volume with the correct manufacturer-specified formulation
  • Placement confirmation: Class K unit confirmed within 30 feet travel distance of all commercial cooking equipment

Restaurant operators who add or relocate cooking equipment after the original extinguisher installation should confirm the Class K unit remains within 30 feet travel distance. A new fryer station 35 feet from the existing extinguisher creates a compliance gap that fire marshals will cite.

System Relationship

How Does the Class K Extinguisher Relate to the Kitchen Hood Suppression System?

The Class K portable extinguisher and the kitchen hood fixed suppression system serve different roles in commercial kitchen fire protection. Both are required and neither substitutes for the other.

Class K Extinguisher vs Kitchen Hood Suppression: Roles and Requirements

South Florida commercial kitchens. Both systems required by NFPA 96. Both require separate annual inspection.

FactorClass K Portable ExtinguisherKitchen Hood Suppression SystemCombined Requirement
PurposeManual backup for kitchen staffAutomatic suppression at cooking appliancesBoth required; neither substitutes for the other
ActivationManual pull pin and discharge by operatorAutomatic via fusible links at appliance levelAutomatic system activates first; portable used for residual fire
CoverageWithin 30 feet of cooking equipmentFixed nozzles over specific cooking appliancesHood covers appliances; extinguisher covers areas hood cannot reach
NFPA standardNFPA 10NFPA 96Both enforced; fire marshal checks both during kitchen inspection
Inspection requirementAnnual by licensed fire equipment dealerSemi-annual by licensed fire protection contractorTwo separate inspections; two separate licensed service scopes
Common gapClass K current; hood system overdueHood system current; Class K expiredFire marshal cites whichever is out of compliance

Florida Fire Solutions inspects both Class K portable extinguishers and kitchen hood fire suppression systems. Combining both under one contractor simplifies scheduling and eliminates gaps.

Restaurant with a Class K extinguisher due and a kitchen hood system needing its semi-annual service? We handle both under one licensed contractor relationship and coordinate the schedule.
Contact Us Today
Service Areas

Wet Chemical Class K Fire Extinguisher Service Across South Florida

Florida Fire Solutions is a licensed fire extinguisher service company covering commercial properties across all four South Florida counties. We inspect, recharge, and certify extinguishers for restaurants, offices, hotels, warehouses, healthcare facilities, and every other commercial occupancy type throughout the region.

01
Miami-Dade County

Miami-Dade County's restaurant market includes tens of thousands of commercial kitchens from standalone restaurants through food truck commissaries and ghost kitchen operations. The Miami-Dade Fire Rescue authority and municipal fire departments check Class K extinguisher compliance during restaurant fire inspections. We serve Miami-Dade restaurants with Class K extinguisher service and coordinated kitchen hood inspection.

View Miami-Dade coverage
02
Broward County

Broward County's restaurant density along the major commercial corridors of Fort Lauderdale, Hollywood, and Pembroke Pines represents one of the highest concentrations of commercial kitchens in South Florida. The Broward County Fire authority enforces Class K and kitchen hood compliance during restaurant inspections. We serve Broward County restaurants with licensed Class K service.

View Broward coverage
03
Palm Beach County

Palm Beach County's restaurant and food service market from Boca Raton through Palm Beach Gardens requires Class K extinguisher inspection alongside kitchen hood service for every commercial kitchen operation. The Palm Beach County Fire Rescue authority enforces both requirements. We serve Palm Beach County food service operations with Class K extinguisher service.

View Palm Beach coverage
04
Monroe County / Florida Keys

Monroe County's restaurant and resort food service market throughout the Florida Keys is a concentrated commercial kitchen environment where Class K extinguisher compliance is actively enforced. Tourist-season staffing changes in Keys properties make reliable annual inspection scheduling especially important. We serve Monroe County restaurant and resort kitchens as a licensed fire extinguisher service company.

View Monroe County coverage
Why Choose Us

Why Florida Fire Solutions for Class K Extinguisher Service

Class K service requires a contractor who understands the relationship between the portable extinguisher and the hood suppression system, tracks both the annual tag and the 5-year hydrostatic test date, and can service both systems.

5-Year Hydrostatic Test Tracking
We track the hydrostatic test date for every Class K unit alongside the annual inspection schedule. Restaurant operators receive notification when the 5-year test is approaching so they are never surprised by a fire marshal finding an overdue test stamp.
Kitchen Hood Suppression System Coordination
We inspect both Class K portable extinguishers and kitchen hood suppression systems. Restaurants that combine both under one contractor eliminate the gap where each contractor assumes the other is handling the adjacent system.
Correct Wet Chemical Agent
Class K wet chemical formulations are manufacturer-specific. We confirm the correct agent formulation for each unit and recharge with the specified agent. Substituting a different formulation affects suppression effectiveness.
Licensed Across All Four Counties
Florida Fire Solutions holds active license #FPC25-000017 and serves restaurants and commercial kitchens with Class K extinguisher service across Miami-Dade, Broward, Palm Beach, and Monroe County.
Common Questions

Frequently Asked Questions: Class K Wet Chemical Extinguisher Service

ABC dry chemical is not effective and is potentially dangerous on commercial cooking oil fires. The discharge force can splash burning oil and spread the fire. NFPA 10 and NFPA 96 specifically require a listed Class K extinguisher for commercial cooking applications.

Yes. Both are required by NFPA 96 for commercial kitchens with deep frying or other high-temperature cooking. The hood suppression system provides automatic protection at the appliance level. The Class K portable extinguisher is the manual backup. Neither substitutes for the other.

Annual inspection by a licensed fire equipment dealer under NFPA 10, plus hydrostatic pressure testing every 5 years. Monthly visual checks are also required and are typically performed by kitchen staff as part of opening procedures.

NFPA 10 requires the Class K extinguisher to be within 30 feet of the cooking equipment along the travel path, not straight-line distance. If a kitchen layout requires walking around equipment to reach the extinguisher, the actual travel path must be measured.

It depends on the travel distance from the existing extinguisher to the new fryer. If the new station is within 30 feet along the travel path, the existing unit may cover both. If it exceeds 30 feet, an additional Class K unit is required at or near the new station.

Ready to schedule Class K extinguisher service for your restaurant? All four South Florida counties. 5-year hydrostatic test tracking. Kitchen hood inspection coordination available.
Request an Appointment

Schedule Your Class K Wet Chemical Extinguisher Service

Call us or send a message. We inspect your Class K unit, track the 5-year hydrostatic test, and coordinate with your kitchen hood suppression inspection. Licensed contractor. All four South Florida counties.

Or call directly (305) 707-3473

Reviewed by the Florida Fire Solutions Team. Licensed fire protection contractor, License #FPC25-000017. Serving Miami-Dade, Broward, Palm Beach, and Monroe County. All content reflects current NFPA 10 / NFPA 96 requirements and Florida fire code standards enforced by the Florida State Fire Marshal.

Last updated: May 2025