Florida Fire Solutions • License #FPC25-000017

Kitchen Hood Wet Chemical Extinguisher Service
Coordinated With Hood System Inspection, South Florida

Licensed Class K wet chemical extinguisher inspection and service for kitchen hood areas across Miami-Dade, Broward, Palm Beach, and Monroe County. Coordinated with your semi-annual hood suppression inspection.

Kitchen Hood Area Extinguishers

What Are the Specific Extinguisher Requirements for Kitchen Hood Areas?

A Class K wet chemical fire extinguisher is required within 30 feet of all commercial cooking equipment under a kitchen hood, per NFPA 96 and NFPA 10. This extinguisher requirement exists independently of the kitchen hood fire suppression system. The hood suppression system provides automatic protection at the appliance level. The Class K portable extinguisher provides manual backup capability for kitchen staff. Both are required. Both must be currently inspected. Florida Fire Solutions services kitchen hood area extinguishers across all four South Florida counties, coordinated with the semi-annual kitchen hood suppression system inspection where both are needed.

The reason NFPA 96 specifically addresses the portable extinguisher requirement in the context of commercial kitchen hood systems is that the two systems address different aspects of commercial kitchen fire protection. The hood suppression system activates automatically when a cooking fire triggers the fusible links or thermal detectors at the cooking appliance level. The Class K portable extinguisher is the tool a kitchen employee uses to address a fire the automatic system did not suppress, a fire outside the hood coverage area, or a residual fire burning on a surface after the automatic system has discharged.

Many South Florida restaurant operators understand that their kitchen hood system needs semi-annual inspection but are unaware that the Class K portable extinguisher adjacent to the hood has its own separate inspection requirement. The hood suppression contractor inspects the fixed system. A separate licensed fire equipment dealer must inspect the portable extinguisher. These are two distinct services with their own inspection frequency and service scope. The Florida State Fire Marshal checks both during restaurant fire inspections, and a restaurant with a current hood system inspection but an expired portable extinguisher tag will still receive a citation.

Florida Fire Solutions holds both the licenses required to service kitchen hood suppression systems and portable fire extinguishers. Restaurants that use us for both services eliminate the coordination gap between two contractors. When we visit for the semi-annual kitchen hood inspection, we simultaneously inspect the Class K portable extinguisher in the same visit. See our full kitchen hood fire suppression inspection program and Class K extinguisher service.

A Current Hood System Tag Does Not Cover the Portable Extinguisher

The kitchen hood suppression system and the Class K portable extinguisher are two separate fire protection systems with two separate inspection requirements. A restaurant with a current hood system tag but an expired portable extinguisher tag will be cited for the extinguisher. Florida Fire Solutions holds license #FPC25-000017 and services both systems, coordinated in the same visit where possible, across all four South Florida counties.

Request a Service Appointment →
Annual
Extinguisher
2x/yr
Hood System
100%
Documented

License #FPC25-000017. Every inspection is documented with a written service report and the extinguisher is tagged per Florida Administrative Code 69A-21 and NFPA 10.

Restaurant with a current hood system inspection but an expired Class K extinguisher tag? Both are checked by fire marshals. We service both in the same visit across all four South Florida counties.
Call (305) 707-3473
Inspection Scope

What Does the Kitchen Hood Area Class K Extinguisher Inspection Include?

The Class K extinguisher inspection in a kitchen hood area follows the standard NFPA 10 annual inspection scope with additional attention to placement relative to cooking equipment.

  • Location confirmed within 30 feet of cooking equipment: travel distance from extinguisher to all cooking equipment under the hood confirmed; new equipment additions assessed for travel distance compliance
  • Accessibility confirmed: extinguisher accessible without obstruction; not behind equipment, inside a cabinet, or in a location requiring a key or tool to access
  • Pressure gauge in operable range: gauge confirmed in green zone; out-of-range reading documented as requiring recharge
  • Physical condition inspected: cylinder, handle, hose, and nozzle inspected for damage, corrosion, or grease accumulation; kitchen environments accelerate grease buildup
  • Tamper seal and pull pin confirmed: seal intact; pin in place; broken or missing seal documented
  • Operating instructions legible: label confirmed legible and facing the approach direction; grease mist in kitchen environments can obscure labels
  • Annual inspection tag current: new annual tag affixed; written service report produced
  • 5-year hydrostatic test status checked: cylinder test stamp assessed; unit scheduled for 5-year test if approaching or past interval
  • Coordination note with hood system record: extinguisher inspection result noted in coordination with the hood system inspection record where both services are performed in the same visit

Kitchen environments are particularly demanding on portable extinguisher condition. Grease mist coats extinguisher surfaces and can accumulate on the pressure gauge face. We clean the gauge face and assess grease accumulation during every kitchen area inspection.

Inspection Coordination

How Should Kitchen Hood System and Portable Extinguisher Inspection Be Coordinated?

Two separate licensed contractors, two separate inspection requirements, two separate compliance deadlines. Understanding the relationship helps restaurant operators avoid the gap where one system is current and the other is not.

Kitchen Hood System vs Class K Extinguisher: Inspection Requirements Compared

South Florida restaurants and commercial kitchens. Both required by NFPA 96. Both checked by fire marshals during restaurant inspections.

FactorClass K Portable ExtinguisherKitchen Hood Suppression SystemCoordination Opportunity
Inspection frequencyAnnual (every 12 months)Semi-annual (every 6 months)Extinguisher can be inspected at either the 6-month or 12-month hood visit
Who performsLicensed fire equipment dealer (NFPA 10)Licensed fire protection contractor (NFPA 96)One contractor holding both licenses can service both in same visit
What is inspectedPortable extinguisher unit: gauge, condition, seal, tagFixed suppression system: agent containers, nozzles, fusible links, gas shutoffDifferent scope; different equipment; different documentation
Fire marshal checkExtinguisher tag and conditionHood system tag and test recordFire marshal checks both; deficiency in either results in citation
Common gap scenarioHood system current; extinguisher expiredExtinguisher current; hood system overdueEach contractor assumes the other is handling the adjacent system
Best practiceCombine both under one contractor holding both licensesSameSingle visit; single point of contact; no gap between systems

Florida Fire Solutions holds both the fire equipment dealer license for portable extinguisher service and the fire protection contractor license for kitchen hood suppression inspection. Restaurants can combine both services in a single visit.

Restaurant currently using separate contractors for the hood system and the portable extinguisher? We hold both required licenses and can combine both inspections in a single scheduled visit.
Contact Us Today
Service Areas

Kitchen Hood Wet Chemical Extinguisher Service Across South Florida

Florida Fire Solutions is a licensed fire extinguisher service company covering commercial properties across all four South Florida counties. We inspect, recharge, and certify extinguishers for restaurants, offices, hotels, warehouses, healthcare facilities, and every other commercial occupancy type throughout the region.

01
Miami-Dade County

Miami-Dade County's restaurant market includes tens of thousands of commercial kitchens where both the hood suppression system and the Class K portable extinguisher require current inspection. The Miami-Dade Fire Rescue authority and municipal fire departments check both during restaurant inspections. We serve Miami-Dade restaurants with coordinated hood suppression and Class K extinguisher service under one licensed contractor relationship.

View Miami-Dade coverage
02
Broward County

Broward County's dense restaurant market throughout Fort Lauderdale, Hollywood, and surrounding communities produces frequent coordination gaps where one system is current and the other is not. The Broward County Fire authority cites both systems independently. We serve Broward County restaurants with combined hood and extinguisher inspection in a single coordinated visit.

View Broward coverage
03
Palm Beach County

Palm Beach County's restaurant and food service market from Boca Raton through Jupiter includes commercial kitchens where coordinating hood suppression and extinguisher inspection under one contractor simplifies compliance management. The Palm Beach County Fire Rescue authority enforces both requirements. We serve Palm Beach County restaurants with coordinated kitchen fire protection inspection.

View Palm Beach coverage
04
Monroe County / Florida Keys

Monroe County's restaurant and resort food service market throughout the Florida Keys requires coordination between hood suppression and Class K extinguisher service that is particularly valuable given the limited availability of licensed fire protection service in the Keys. Having one contractor hold both licenses reduces the number of service relationships a Keys restaurant operator must maintain. We serve Monroe County restaurants with coordinated kitchen fire protection service.

View Monroe County coverage
Why Choose Us

Why Florida Fire Solutions for Kitchen Hood Area Extinguisher Service

The kitchen hood area is the one location in a South Florida restaurant where two separate licensed service requirements intersect. Having one contractor cover both eliminates the gap that produces citations.

Both Licenses, One Visit
We hold the fire equipment dealer license required for portable extinguisher service and the fire protection contractor license required for kitchen hood suppression system inspection. Both services in one scheduled visit, one service report, one point of contact.
30-Foot Travel Distance Confirmed
We physically confirm the 30-foot travel distance from the Class K extinguisher to every piece of cooking equipment under the hood during every inspection. New equipment additions that create a travel distance gap are flagged immediately.
Grease Environment Assessment
Kitchen environments coat extinguisher surfaces with grease mist. We assess grease accumulation on the extinguisher exterior, clean the gauge face, and document any condition concerns during every inspection.
Licensed Across All Four Counties
Florida Fire Solutions holds active license #FPC25-000017 and serves restaurants and commercial kitchens with Class K extinguisher and hood suppression inspection across Miami-Dade, Broward, Palm Beach, and Monroe County.
Common Questions

Frequently Asked Questions: Kitchen Hood Area Extinguisher Service

Not necessarily. The kitchen hood suppression system requires a licensed fire protection contractor under Florida Statute 633.521. The Class K portable extinguisher requires a licensed fire equipment dealer under Florida Statute 633.508. If your contractor holds both licenses they can service both. Florida Fire Solutions holds both licenses and can service both systems in the same visit.

The portable extinguisher should be inspected following any hood system discharge even if the extinguisher was not used. The discharge event may have physically disturbed the extinguisher, broken the tamper seal, or resulted in kitchen staff using the extinguisher without reporting it.

It depends on the travel distance from the existing extinguisher to the new cooking line. If any piece of cooking equipment on the new line is more than 30 feet from the existing extinguisher along the travel path, an additional Class K unit is required.

The Class K extinguisher must be within 30 feet travel distance. It should not be directly above or immediately adjacent to the cooking equipment since a fire at the appliance could block access. A mounted position near the kitchen exit or in a visible location accessible from the approach direction to the cooking area is typical.

Grease accumulation is common but should be cleaned during the annual inspection. Heavy grease accumulation on the nozzle or hose connection should be assessed to confirm it has not entered the discharge path. We clean the gauge face and assess grease condition at every kitchen area inspection visit.

Ready to schedule kitchen hood area extinguisher service coordinated with your hood system inspection? All four South Florida counties. Both licenses held. Both services in one visit.
Request an Appointment

Schedule Your Kitchen Hood Extinguisher Service

Call us or send a message. We inspect the Class K extinguisher, confirm the 30-foot travel distance, coordinate with the hood system inspection, and deliver combined documentation. Licensed contractor. All four South Florida counties.

Or call directly (305) 707-3473

Reviewed by the Florida Fire Solutions Team. Licensed fire protection contractor, License #FPC25-000017. Serving Miami-Dade, Broward, Palm Beach, and Monroe County. All content reflects current NFPA 96 / NFPA 10 requirements and Florida fire code standards enforced by the Florida State Fire Marshal.

Last updated: May 2025